Vertical Platform Lift Products - BC and HBC Model FEATURES
- Capacity: 750 lbs. (700# - RE)
- Speed: Acme Screw - 9 fpm, Hydraulic - 20 fpm
- Drive System:
- Acme Screw: Motor minimum of 3/4 HP, instant reverse, 1750RPM, 115 VAC, single phase. (220 volt optional) Acme screw drive with back-up safety nut and auto-lubrication system or -
- Hydraulic: 24 VDC 1 1/2 HP. Drive= 1:2 Leaf chain hydraulic w/type "A" instantaneous slack chain safety device
- Static/Running Load Test: All load ratings and safety factors shall meet or exceed those specified in ASME A18.1
The units are be equipped with the following safety features:
- Upper and lower limit switches
- Final limit switch
- Secondary safety nut (Acme Screw) or Slack Chain Device (Hydraulic)
- 24V low voltage controls
- Grounded electrical system
- 42" side guards (36" residential)
- Non-skid platform and access ramp
- Key-lock controls
- Platform safety pan or Runway Enclosure
- Emergency stop/alarm
- Top and bottom landing gates/doors provided with combination mechanical lock and electrical contact. (Local code may vary)
- Grab rail
- Platform is constructed of 12-gauge minimum zinc clad steel. If unit is not installed in a 3-inch pit, a stationary ramp shall be provided that extends under the lower landing gate/door.
- Platform side panels must be 42" high. Side panel frame shall be a min. 1" x 1 1/2" x .065 tubing (outdoor units aluminum). The solid infill panels shall be a min. of 24 gauge zinc clad steel.
- Main frame tubings shall be square or rectangular tubing with a minimum. 120 wall thickness.
- Carriage assembly arms shall be a minimum of 1" wide steel flatbar along with 1/2" thick steel flatbar uprights. Cam rollers shall be used for axial carriage guidance and wear pads used for horizontal stability. Unit to be equipped with the "simplex" base and carriage design, which allows the carriage to be folded to reduce the shroud and carriage width to 18" without removal of any carriage attaching bolts. On Hydraulic units, cam rollers shall be supported by a minimum 6.25#/ft. "T" rail with tongue and groove ends mated at the split sections of the machine tower.
- Loaded fasteners shall be grade five or higher. Locking fasteners shall be used in all critical locations.
- Machine Tower
|
|