SUGGESTED SPECIFICATIONS
PART 1 - GENERAL
1.1 SCOPE
To furnish all labor, materials and equipment necessary or required to
complete the installation of the lift as indicated on the Drawings and
Specifications. This specification is intended to cover the complete installation
of the Concord HANDILIFT-EN (ENCLOSED) Vertical Wheelchair Platform Lift
design.
1.2 SYSTEM DESCRIPTION
Lift assembly shall consist of a platform, guide system, panels and gates,
self-contained Acme Screw drive unit, control system, signals and alarms,
electrical wiring, and parts and accessories necessary to provide required
performance operation and code and safety requirements.
|
1.3 QUALITY ASSURANCE
1.3.2 Requirements of the Regulatory Agencies
a) Fabricate and install work in compliance with all applicable jurisdictional
authorities.
b) File shop drawings and submissions to local authorities as the information
is made available. Company pre-inspection and jurisdictional authority inspections
and permits are to be made on a timely basis as required. Work will include
all inspections and re-inspections required to ensure licenses are issued. |
1.3.3 Subcontractor Qualifications
a) Execute work of this specification only by a contractor/company who has
adequate product and public liability insurance in excess of one million
dollars.
b) Skilled tradesmen must be employees of the contractor and perform the
work on a timely basis. Employees must be trained by the manufacturer and
be supervised by the lift contractor.
1.3.4. Substitutions
No substitutions will be considered unless written request for approval
has been submitted by the bidder and received by the architect at least
10 days before the date of receipt of bids. Each such request shall include
a complete description of the proposed substitute including drawings, test
data, photographs, and any other information needed for consideration. |
PART 2 - PREPARATORY WORK BY OTHERS
2.1 The following preparatory work to accommodate the
lift is to be done by others:
2.1.1 Permanent 110 volt 20 amp min. power to operate the lift to be provided
from a Lockable Fused/Cartridge Type Disconnect Switch. Refer to architectural
drawings for permanent power specifications and location of disconnect.
Temporary power may be provided to expedite the installation of lift.
2.1.2 Provide clear access to lift installation location and remove all
obstacles before lift delivery and installation.
2.1.3 Provide adequate overhead clearances as required by the applicable
code and as per drawings.
2.1.4 Provide a substantial level floor (pit) slab as indicated on lift
contractors shop drawings.
2.1.5 Provide finish grouting, and masonry around walls, ceilings, and
doors.
2.1.6 Provide adequate lighting at lift areas as required by the applicable
code.
|
PART 3 - SUBMITTALS
3.1 SHOP DRAWINGS
The shop drawings shall show a complete layout of the lifting equipment
detailing dimensions, clearances and location of lift equipment. Including
the following:
a) Drawings showing the dimensions including plans, elevations, and sections
to show equipment locations and their relationship to surroundings.
b) Anchorage and clearance requirements.
c) Load and reaction drawings.
|
3.2 SAMPLES
|
PART 4 - PRODUCT DATA
4.1 MANUFACTURER / PRODUCT
Lift shall be the Concord HANDILIFT-EN (ENCLOSED) Vertical Wheelchair
Platform Lift by: Mobility Elevator, 4 York Avenue, West Caldwell, NJ - PH: (800) 441-4181 or (973) 618-9545 - FAX: (973) 618-9638
|
| Rated Load: |
750 lbs. (341 kg) |
| Normal Speed: |
8 fpm (0.04 m/s) |
| Platform Dimensions: |
|
| Levels Served: |
2 |
| Travel Distance (Up to 12' (3658m)
max): |
see drawings ______________
|
| Operation: |
Constant Pressure |
| Power Supply: |
110 Volts, 1 Phase, 20 Amps |
| Drive Type: |
Acme Screw |
| Motor: |
1 HP |
| Paint: |
Baked Polyester Gloss Powder |
4.2 SIGNAGE
4.2.1 The lift shall have all necessary signs, capacity plates, and data
signs as per the Local and national Codes and Standards.
4.2.2 A capacity plate indicating the rated load in pounds and kilograms
and operating instructions shall be furnished by the manufacturer and fastened
in a conspicuous place at each landing and in the platform. The capacity
plate and operating instructions will be engraved on non-glare, micro-surface,
white letters on a blue background, self-adhesive, flexible plastic material.
The letters and figures stating the capacity shall not be less than 1/4"
in height.
4.3 LIFT PLATFORM (CAR)
4.3.1 FRAME AND SIDE GUARD PANELS
Aluminum platform frame 42 1/4" high (1073 mm) with steel insert.
4.3.2 FLOOR
Formed steel with anti-slip sheeting.
4.3.3 GRAB RAIL
A single grab rail with both ends returned to the wall shall be located
on the control wall of the carriage.
4.3.4 CAR OPERATING PANEL
Shall consist of constant pressure illuminated buttons,, an emergency stop
and alarm button, low oil indicator light, and an ON/OFF key switch mounted
on a removable stainless steel panel (type 304 #4 stainless steel finish).
The key shall only be removable when the key is in the OFF position.
4.4 ENCLOSURE
4.5 DRIVE UNIT AND CONTROLS
The drive unit and controller shall be enclosed in the mast. The controller
and drive unit shall be pre-wired and tested before shipment. Control
circuitry is to be PCB mounted as an integral unit.
4.6 ACME SCREW
1" O.D. , Class 2G, 5 pitch. Self-lubricating nut and screw drive.
4.7 SAFETY DEVICE
Integral "Back up" Safety Nut. In the event of failure of the
main drive nut, the "Back up" Safety Nut will engage and trip
a switch to stop the car automatically.
4.8 NORMAL TERMINAL STOPPING DEVICES
Normal terminal stopping devices shall be electro-mechanically sensed
at the top and bottom of runway to stop the car automatically.
4.9 FINAL LIMIT STOPPING DEVICE
A final stopping device shall be electrically sensed and stop the lift
should the lift pass the upper normal terminal stopping device and remove
electrical power to the control circuit.
4.10 PIT SWITCH
Switch located at the base of the mast, when tripped will remove electrical
power to the control circuit and stop the operation of the car.
4.11 EMERGENCY MANUAL LOWERING
The top of the Acme Screw must be accessible and equipped such that the
screw may be turned by using a hand crank to lower the platform.
|
4.12 GUIDE RAILS AND BRACKETS
4.12.1 Steel "T" guide rails and brackets shall be used to
guide the platform and sling.
4.12.2 Guide rail shall form part of the structural integrity of the
unit and be integral to the mast enclosure, ensuring stability and minimum
platform deflection when loaded.
4.13 CAR SLING
4.13.1 Car sling shall be fabricated from steel members with adequate
bracing to support the platform and car.
4.13.2 Guide shoes shall be mounted on the top and bottom of the car sling
to engage the guide rails.
4.13.3 Guide shoes to be solid slipper type.
4.13.4 The car sling arms shall be detachable.
4.14 WIRING
All wiring and electrical connections shall comply with applicable Codes,
insulated wiring shall have flame retardant and moisture proof outer covering
and shall be run in conduit or electrical wire ways.
4.15 FINISH
Electrostatically applied baked polyester powder coating paint finish.
|
PART 5 - EXECUTION
5.1 EXAMINATION
All site dimensions shall be taken to ensure that tolerances and clearances
have been maintained and meet local regulations.
5.2 PREPARATION
Pre-inspect the construction and service requirements for "Work by
Others." These requirements will be included in drawings, diagrams,
engineering data sheets and special instructions before the work commences.
|
PART 6 - WARRANTY
The lift contractor shall provide three (3) months
free service from date of approval by local authorities. The entire lift
and all component parts shall carry a one (1) year limited warranty. The
warranty shall be for the replacement at no cost of defective parts but
shall not include the labor costs required to replace the defective part
or parts. |
PART 7 - OWNERS INSTRUCTION AND MANUAL
After installation is completed, the contractor shall instruct the
owner in the proper use, operation and maintenance requirements of the lift.
Instructions to also include emergency procedures and safety rules and precautions.
Contractor shall also supply the owner with an Owners Manual detailing